GD30K2-12 Axial Flow Fan

GD30K2-12 Axial Flow Fan

The GD30K2-12 Ducted Axial Flow Fan is an industrial axial ventilation fan designed for factory ventilation, air exchange, equipment cooling, heat removal, and general industrial airflow applications.
Send Inquiry

Product Overview

 

The GD30K2-12 Ducted Axial Flow Fan is an industrial axial ventilation fan designed for factory ventilation, air exchange, equipment cooling, heat removal, and general industrial airflow applications.

With an axial airflow configuration, the fan provides a direct air path through the impeller and is suitable for applications requiring large airflow with relatively low to medium system resistance.

EMS can configure the GD30K2-12 according to the required airflow, pressure, motor power, voltage, temperature, installation arrangement, and operating conditions.

 

Product Names for Overseas Markets

 

Recommended search-oriented product names include:

  • GD30K2-12 Ducted Axial Flow Fan
  • GD30K2-12 Axial Fan
  • GD30K2-12 Industrial Axial Fan
  • GD30K2-12 Axial Ventilation Fan
  • GD30K2-12 Industrial Ventilating Fan
  • GD30K2-12 Axial Flow Ventilation Fan

For the main product title, GD30K2-12 Ducted Axial Flow Fan is recommended because it combines the specific model number with commonly used industry terminology.

Main Applications

 

The GD30K2-12 axial fan can be used for:

  • Industrial Workshop Ventilation
  • Factory Exhaust
  • Industrial Air Exchange
  • Equipment Cooling
  • Steel Plant Ventilation
  • Machinery Workshop Ventilation
  • Warehouse Ventilation
  • Mining Ventilation
  • Tunnel and Underground Ventilation
  • Local Industrial Exhaust
  • Heat Removal
  • General Industrial Air Circulation

 

Typical Installation Locations

 

GD30K2-12 Duct Axial Flow Fan

Industrial Workshops

For ventilation and heat removal in machinery, manufacturing, and production facilities.

Steel and Metallurgical Plants

For production-area ventilation, equipment cooling, and local air circulation.

Warehouses

For air exchange and heat removal in large enclosed spaces.

Mining Facilities

For auxiliary or local ventilation where the system conditions are suitable for axial fan operation.

Industrial Equipment Cooling

For forced-air cooling of machinery, motors, and production equipment.

Industrial Axial Flow Fan

 

Typical Technical Parameters

 

Parameter

Typical Range / Configuration

Fan Type

Ducted Axial Flow Fan

Model

GD30K2-12

Fan Diameter

1200 mm

Airflow

Application Dependent

Pressure

Application Dependent

Fan Speed

Application Dependent

Motor Power

Application Dependent

Motor Type

Three-Phase Industrial Motor

Drive Type

Direct Drive

Blade Type

Axial Flow Impeller

Installation

Horizontal / Vertical

Fan Casing

Carbon Steel

Impeller Material

Carbon Steel / Customized

Operating Mode

Continuous Duty

Rotation Direction

Customized

Motor Voltage

Customized

Frequency

50 / 60 Hz

Final airflow, pressure, speed, and motor power should be confirmed according to the actual impeller configuration and project duty point. These values should not be treated as fixed performance specifications without technical confirmation.

 

Key Design Features

 

Axial Airflow

Air moves along the fan shaft, making the fan suitable for high-volume ventilation and air circulation applications.

 

Compact Construction

The axial configuration provides a relatively compact airflow path and can be suitable where installation space is limited.

 

High Airflow Capacity

Designed for applications requiring substantial air exchange, ventilation, or heat removal.

 

Direct Drive

The motor can directly drive the impeller, reducing the number of transmission components and simplifying maintenance.

 

Industrial Construction

Housing, impeller, flanges, and motor mounting structures can be reinforced for continuous industrial operation.

 

Customized Configuration

EMS can customize:

  • Fan Direction
  • Motor Power
  • Motor Voltage
  • Blade Configuration
  • Casing Material
  • Flange Design
  • Installation Structure
  • Explosion-Proof Motor Configuration

 

Axial Fan vs. Centrifugal Fan

 

The GD30K2-12 is an axial flow fan, mainly intended for high-volume ventilation, direct airflow, and relatively low to medium system resistance.

For applications involving:

  • Long duct systems
  • High system resistance
  • High static pressure
  • Dust collection
  • High-pressure gas transportation

An Industrial Centrifugal Fan may be considered based on the actual airflow and pressure requirements.

For the EMS website, axial fans and centrifugal fans can therefore be developed as separate product categories.

 

Installation and Operation

 

Before Installation

Check:

  • Fan model
  • Motor power
  • Voltage and frequency
  • Impeller rotation direction
  • Foundation and support structure
  • Inlet and outlet connections
  • Flanges and fasteners

 

Before Start-Up

Make sure the impeller is free from foreign objects and rotates smoothly. Check that electrical connections comply with applicable local requirements.

 

During Operation

Monitor:

  • Rotation Direction
  • Motor Current
  • Vibration
  • Noise
  • Airflow
  • Bearing Temperature

Stop the fan if abnormal vibration, excessive noise, abnormal current, or abnormal bearing temperature occurs.

 

Routine Maintenance

Regularly inspect:

  • Motor
  • Bearings
  • Impeller
  • Fasteners
  • Flanges
  • Electrical Connections
  • Fan Vibration

Maintenance intervals should be determined according to operating hours, dust levels, ambient conditions, and actual service requirements.

 

Hot Tags: gd30k2-12 axial flow fan, China gd30k2-12 axial flow fan suppliers, factory, Axial Cooling Fan, axial flow fans, GD30K2 12 Axial Flow Fan, GD30K2 12 Duct Axial Flow Fan, Industrial Axial Flow Fan, Wire Rod Air Cooling Axial Flow Fan