Product Overview
The FRP centrifugal fan is a corrosion-resistant industrial centrifugal fan manufactured with fiberglass-reinforced plastic (FRP). It is designed for conveying acidic, alkaline, saline and other corrosive gases in industrial ventilation and exhaust systems.
EMS supplies customized FRP Centrifugal Fans for chemical plants, electroplating facilities, wastewater treatment, scrubber systems, industrial waste gas treatment, electronics manufacturing and other applications where corrosion resistance is required.
Main Applications
- Chemical Exhaust Systems
- Corrosive Gas Exhaust
- Acid Fume Exhaust
- Alkali Gas Exhaust
- Electroplating Exhaust
- Chemical Plant Ventilation
- Laboratory Exhaust
- Industrial Waste Gas Treatment
- Scrubber Exhaust
- VOC Exhaust Systems
- Pickling Line Exhaust
- Electronics Manufacturing
- Wastewater Treatment Ventilation
- Corrosive Air Ventilation
Typical Technical Parameters
|
Parameter |
Typical Range |
|
Fan Type |
FRP centrifugal fan |
|
Airflow |
1,000–80,000 m³/h |
|
Total Pressure |
500–3,000 Pa |
|
Motor Power |
0.75–110 kW |
|
Fan Speed |
730–2,900 rpm |
|
Gas Temperature |
Typically ≤80°C |
|
Impeller Material |
FRP |
|
Casing Material |
FRP |
|
Drive Type |
Direct Drive / Belt Drive |
|
Fan Structure |
Single-Suction Centrifugal |
|
Bearing |
Industrial Bearing |
|
Installation |
Horizontal / Customized |
|
Frequency |
50 Hz / 60 Hz |
|
Operation |
Continuous Duty |
Engineering Note: These are typical reference ranges rather than fixed specifications for every 4-72 configuration. Actual performance depends on fan size, airflow, pressure, gas temperature, gas composition and total system resistance.
Working Principle
Corrosive gas enters the fan through the inlet and is accelerated by the rotating FRP centrifugal impeller. Centrifugal force increases the gas velocity and pressure while changing the airflow direction. The volute collects and guides the gas toward the discharge duct and downstream treatment equipment.
Typical process:
Corrosive Gas → 4-72 FRP Fan → Scrubber → Gas Treatment → Exhaust Stack
Alternative process:
Production Equipment → FRP Exhaust Fan → Duct → Waste Gas Treatment System
Key Features

Excellent Corrosion Resistance
FRP construction provides corrosion resistance for many acidic, alkaline and chemically aggressive gas environments.
Designed for Chemical Exhaust
The fan is suitable for acid fumes, alkaline gases, chemical process exhaust and other corrosive industrial ventilation applications.
Lightweight FRP Construction
FRP provides a lightweight alternative to conventional metal fan construction while offering strong resistance to many corrosive environments.
Multiple Fan Sizes
Different fan sizes can be selected according to airflow, pressure, duct dimensions and available installation space.
Compatible with Scrubber Systems
The 4-72 FRP fan can be integrated with scrubbers, absorption towers and industrial waste gas treatment systems.
Customized Engineering
EMS can customize the fan according to gas composition, concentration, temperature, airflow, pressure, materials, motor power, drive type and installation requirements.

Typical Industries
Chemical Industry
Chemical Plants
Chemical Processing Lines
Acid and Alkali Production
Chemical Storage Areas
Corrosive Gas Exhaust
Electroplating & Surface Treatment
Electroplating Plants
Pickling Lines
Metal Surface Treatment
Acid Cleaning Systems
Environmental Protection
Scrubber Systems
Industrial Waste Gas Treatment
Corrosive Exhaust Systems
VOC Treatment Systems
Electronics & Semiconductor
Electronics Manufacturing
Semiconductor Facilities
PCB Production
Chemical Exhaust Systems
Wastewater Treatment
Wastewater Treatment Plants
Chemical Storage
Corrosive Gas Exhaust
Odor Control Systems
Fan Selection Information
For proper selection of a FRP centrifugal fan, customers should provide:
- Required Airflow
- Total or Static Pressure
- Gas Temperature
- Gas Composition
- Corrosive Medium
- Gas Concentration
- Dust or Particulate Content
- Duct Size and Length
- Scrubber / Treatment Equipment Resistance
- Motor Voltage and Frequency
- Installation Position
- Operating Hours
Important: FRP material selection should not be based only on whether the gas is "acidic" or "alkaline." Different chemicals, concentrations and temperatures have different compatibility requirements. The final resin and FRP configuration should be selected according to the actual gas composition and operating conditions.
EMS Engineering & Technical Services
EMS provides complete engineering support for FRP anticorrosion fan projects:
- Fan Selection
- Airflow & Pressure Calculation
- Corrosion Resistance Assessment
- FRP Material Selection
- Impeller Design
- Motor Matching
- Drive Selection
- Scrubber System Matching
- Customized Inlet / Outlet Direction
- VFD Configuration
- Factory Performance Testing
- Export Packaging
- Installation Guidance
- Spare Parts
- Technical Support
Hot Tags: 4-72 frp anticorrosion centrifugal fan, China 4-72 frp anticorrosion centrifugal fan suppliers, factory, 4 72 Chemical Exhaust Fan, 4 72 FRP Anticorrosion Centrifugal Fan, 4 72 FRP Anticorrosion Fan, anticorrosion fans