Product Overview
The SDS Tunnel Jet Fan is an axial-flow jet fan designed for longitudinal ventilation in road tunnels, highway tunnels, underground roads, transportation tunnels, and other large underground facilities.
By generating high-velocity airflow and jet thrust, the fan transfers momentum to the surrounding tunnel air and drives longitudinal airflow through the tunnel. It can be used for normal ventilation, pollutant removal, airflow control, and smoke management during fire emergencies.
EMS provides SDS Tunnel Jet Fans with customized airflow, jet thrust, motor power, reversible operation, high-temperature configuration, mounting systems, and electrical control solutions according to individual tunnel projects.
Main Applications
SDS Tunnel Jet Fans are suitable for:
- Road Tunnel Ventilation
- Highway Tunnel Ventilation
- Urban Road Tunnel Ventilation
- Underground Road Ventilation
- Railway and Transit Tunnels
- Underground Parking Facilities
- Long Underground Passages
- Tunnel Pollutant Exhaust
- Tunnel Smoke Control
- Fire Smoke Management
- Longitudinal Tunnel Ventilation
- Underground Transportation Facilities

Typical Technical Parameters
|
Parameter |
Typical Range |
|
Product Type |
Tunnel Jet Fan |
|
Fan Diameter |
500–1600 mm |
|
Airflow |
20,000–150,000 m³/h |
|
Jet Velocity |
20–40 m/s |
|
Jet Thrust |
300–2,500 N |
|
Motor Power |
7.5–160 kW |
|
Motor Speed |
1,450–2,980 rpm |
|
Operating Temperature |
-20°C to +60°C |
|
High-Temperature Operation |
Optional |
|
Airflow Direction |
Forward / Reversible |
|
Drive Type |
Direct Drive |
|
Impeller Type |
Axial Flow |
|
Casing Material |
Carbon Steel / Stainless Steel |
|
Motor |
Industrial / Tunnel Ventilation Motor |
|
Installation |
Ceiling / Side Mounting |
|
Control |
DOL / Soft Starter / VFD |
|
Duty |
Continuous Operation |
The above values are typical engineering reference ranges rather than fixed specifications for every SDS model. Final fan performance should be selected according to the tunnel ventilation calculation, required jet thrust, smoke-control conditions, and applicable project standards.
Working Principle
The SDS Tunnel Jet Fan uses an axial impeller to accelerate air through the fan and generate a high-speed jet.
The resulting jet exchanges momentum with the surrounding tunnel air, creating longitudinal airflow along the tunnel.
Typical ventilation flow:
Fresh Air → SDS Jet Fan → Longitudinal Airflow → Pollutant Exhaust
For emergency smoke-control applications, multiple jet fans can be strategically installed and controlled to manage smoke movement and support the tunnel's fire safety ventilation system.
Key Features

High Jet Thrust
The aerodynamic design of the axial impeller and internal airflow passage is optimized to generate effective jet thrust for tunnel longitudinal ventilation.
Reversible Operation
Reversible configurations can be provided for projects requiring bidirectional airflow or specific smoke-control strategies.
Compact Installation
Jet fans are normally suspended from the tunnel ceiling or mounted on brackets, minimizing the need for large ventilation ducts.
Direct Drive
The direct-drive configuration reduces mechanical transmission components and simplifies inspection and maintenance.
High-Temperature Configuration
For fire smoke-control applications, the fan can be engineered with appropriate high-temperature materials, motor configuration, insulation, and other components according to the required duty.
Customized Engineering
EMS can select and customize the fan according to tunnel length, cross-sectional area, ventilation resistance, required airflow, jet thrust, installation conditions, power supply, and smoke-control requirements.

Typical Installation Locations
SDS Tunnel Jet Fans can be installed in:
- Tunnel ceilings
- Tunnel roofs
- Tunnel side walls
- Ventilation sections
- Underground roadways
- Smoke-control zones
- Underground transportation facilities
Multiple jet fans can be arranged according to the tunnel ventilation design to establish the required longitudinal airflow pattern.
Fan Selection Information
To select the appropriate SDS Tunnel Jet Fan, the following information is recommended:
- Tunnel Length
- Tunnel Cross-Section
- Tunnel Height
- Traffic Volume
- Required Airflow
- Required Jet Thrust
- Ventilation Method
- Ventilation Resistance
- Smoke Extraction Requirement
- Fire Temperature Requirement
- Fan Installation Height
- Power Supply
- Voltage and Frequency
- Reversible Operation Requirement
- Noise Requirement
- Required Fan Quantity
EMS can provide fan selection and engineering recommendations based on the actual project conditions.
EMS Engineering & Customization Services
EMS provides more than standard tunnel jet fans. Our engineering support can include:
- Fan Selection
- Performance Matching
- Airflow and Pressure Calculation
- Jet Thrust Selection
- Motor Selection
- High-Temperature Design
- Reversible Fan Configuration
- Noise Control
- Mounting Bracket Design
- Electrical Control Configuration
- VFD / Soft Starter Configuration
- Technical Documentation
- Export Packaging
- Installation Guidance
- Project-Based Technical Support
Hot Tags: sds tunnel jet fan, China sds tunnel jet fan suppliers, factory, Highway Tunnel Fan, Long Distance Forced Draft Fan, SDF Tunnel Ventilation Fan, SDS Tunnel Jet Fan, Tunnel Construction Fan, Tunnel Ventilation Jet Fan